Highland Ridge Open Range – Furnace Igniter & Control Board Replacement

Complete repair guide for the Highland Ridge Open Range – Furnace Igniter & Control Board Replacement. Follow these steps to diagnose and fix the issue yourself.

Parts & Tools You’ll Need

Disclosure: This post contains affiliate links. We may earn a commission on qualifying purchases at no extra cost to you.

Step-by-Step Repair Guide

Step 1: Diagnose Furnace Ignition Failure

Begin by turning off your RV’s propane supply and electrical power to the furnace system for safety. Use your digital multimeter to test the igniter electrode for continuity and check the control board for any visible burn marks or corrosion that indicate failure.

Step 2: Disconnect Power and Propane

Switch off the main electrical breaker to your furnace and close the propane shutoff valve located at your RV’s main tank or regulator. Allow the furnace to cool completely for at least 30 minutes before proceeding with removal.

Step 3: Remove Old Furnace Components

Unbolt the access panel covering your furnace and disconnect all wiring harnesses from the failing igniter electrode and control board. Carefully remove the old igniter assembly and circuit board, noting the exact positions of wire connections for reinstallation.

Step 4: Install New Igniter Electrode

Position your new furnace igniter electrode assembly into the burner chamber, ensuring it sits at the correct distance from the burner surface. Secure the assembly with mounting bolts and reconnect the wire harness to the control board terminal.

Step 5: Mount Replacement Control Board

Install the new furnace circuit board in its mounting bracket, ensuring proper ventilation around the component to prevent overheating. Connect all wiring harnesses including the sail switch, high-limit switch, and blower motor leads according to your original connection diagram.

Step 6: Verify Sail and Limit Switches

Test that your furnace sail switch moves freely without obstruction and that the high-limit switch clicks when heated with a heat gun. Replace either switch if it fails to respond or shows signs of damage during testing.

Step 7: Test Complete Furnace Operation

Restore propane and electrical power, then set your thermostat to heat mode and listen for the igniter spark and burner ignition within 30 seconds. Use your multimeter to confirm proper voltage at the blower motor and verify your propane/CO detector alarm functions correctly once the furnace cycles.

Recommended Parts

PartLink
Suburban/Atwood RV furnace replacement unitView on Amazon
Furnace igniter electrode assemblyView on Amazon
Furnace sail switchView on Amazon
Furnace circuit board / control boardView on Amazon
Furnace high-limit switchView on Amazon
Furnace blower motor (12V DC)View on Amazon
Propane/CO combo detector alarmView on Amazon
Digital multimeter (auto-ranging)View on Amazon