Step 1: Diagnose Furnace Problems Safely

Before beginning any work, ensure your RV is parked on level ground with the propane system shut off at the tank and all electrical systems disconnected. Use your digital multimeter to test for voltage at the furnace control board and listen for clicking sounds from the igniter electrode, which indicates whether the problem is electrical or mechanical in nature.

Step 2: Remove Old Furnace Assembly

Locate your Suburban or Atwood furnace unit (typically mounted in a cabinet or wall compartment) and disconnect all electrical connectors from the control board, blower motor, and sail switch. Remove the mounting bolts securing the furnace to the frame and carefully slide the entire unit out, noting the propane line connection points for reinstallation reference.

Step 3: Install New Furnace Unit

Position your replacement Suburban/Atwood furnace into the same mounting location and secure it with the original or new mounting bolts. Reconnect the propane line using a new shutoff valve and double-check all connections for leaks using soapy water before proceeding with electrical connections.

Step 4: Connect Control Board Components

Install the new furnace circuit board and reconnect the igniter electrode assembly, sail switch, and high-limit switch according to your RV’s wiring diagram. Ensure the 12V DC blower motor is properly connected to the control board terminals, as these components work together to regulate furnace operation and safety.

Step 5: Secure Igniter Electrode Assembly

Position the igniter electrode assembly into the combustion chamber mounting bracket, ensuring it sits at the correct distance from the burner port as specified in your furnace manual. Tighten the mounting hardware securely so vibration during travel won’t dislodge the electrode and interrupt the ignition spark.

Step 6: Install Propane CO Detector

Mount your propane/CO combo detector alarm in a central location inside the RV where you’ll easily hear audible alarms, typically near sleeping areas. Connect it to a 12V power source and ensure the detector has a clear path for air circulation so it can function properly.

Step 7: Test All Furnace Functions

Reconnect your RV’s electrical system and propane tank, then set the thermostat to heat mode and observe whether the igniter electrode sparks and the blower motor engages within 30 seconds. Use your digital multimeter to verify proper voltage at the control board and listen for the blower motor running smoothly; if the furnace cycles on and off normally while the CO detector remains silent, your replacement is successful.

Recommended Parts

PartLink
Suburban/Atwood RV furnace replacement unitView on Amazon
Furnace igniter electrode assemblyView on Amazon
Furnace sail switchView on Amazon
Furnace circuit board / control boardView on Amazon
Furnace high-limit switchView on Amazon
Furnace blower motor (12V DC)View on Amazon
Propane/CO combo detector alarmView on Amazon
Digital multimeter (auto-ranging)View on Amazon