This post contains affiliate links. As an Amazon Associate, I earn from qualifying purchases at no extra cost to you. After years on the road, I’ve learned that the thermostat is almost always the first thing to go on a Suburban water heater — and having the right replacement on hand saves you from a week of cold showers at some campground with no parts store in sight. The Suburban 232306 Thermostat Switch is a direct OEM-spec replacement, which means no adapter headaches and no guessing whether the wiring will match up. Snap it in, connect the leads, and you’re back to hot water the same afternoon.
I keep a spare heating element tucked in my repair kit specifically because this is a failure you’ll feel immediately — usually right before a long travel day. The Upgraded 520900 RV Water Heater Element for Suburban SW Series is the one I reach for first. It’s built to the same specs as the original but with reportedly better corrosion resistance on the element sheath — something worth caring about if you’ve ever dealt with hard water scaling. Just make sure you drain the tank completely before you start wrenching, or you’ll be mopping up a very unpleasant surprise.
If the 520900 is backordered or you just want a solid budget-friendly backup, the Lrichy 110V/1400W Screw-In RV Water Heater Heating Element has earned a spot in my toolkit. It’s a universal screw-in design rated at 110V/1400W, which matches the Jayco North Point’s electric water heater setup perfectly. The installation is straightforward — standard 1-inch thread, no special tools needed beyond a socket wrench and some plumber’s tape on the threads. Good to have as a carry-along spare when you’re heading somewhere remote.
Step 1: Safety Preparation and Diagnosis
Most of the service calls I get aren’t emergencies — they’re deferred maintenance that finally gave up. The owner noticed something off weeks ago, ignored it, and now they’re calling me from a campground two states from home. Nine times out of ten, this repair could have been done for a fraction of the cost if they’d caught it early. With water heater failures specifically, the story is almost always the same: the thermostat starts cycling inconsistently, the water stops getting reliably hot, and instead of pulling the access panel and running a quick resistance test with a multimeter, the owner keeps resetting the unit and hoping for the best — right up until the heating element burns out completely and now they’re replacing two components instead of one. On the Jayco North Point, the water heater is accessible and the thermostat and heating element are straightforward to test and swap out yourself, so this guide will walk you through exactly what I do when I roll up to one of these rigs on a service call — the right way, in the right order, without skipping the steps that actually matter.
Step 2: Testing and Removing Failed Components
Test the heating element first to determine if replacement is necessary. With power disconnected and the water heater drained, disconnect one of the power wires from the heating element terminal. Set your digital multimeter to the resistance (ohms) setting. Place one probe on each terminal of the heating element. A functional heating element should show a resistance reading between 8-15 ohms, typically around 10-12 ohms for standard RV water heater elements. If your multimeter displays “OL” (overload) or an infinite reading, the heating element has failed and requires replacement. Any reading significantly outside the 8-15 ohm range also indicates a faulty element. If the heating element tests faulty, proceed with removal. Using an appropriate wrench (typically 1-1/8″ or 1-1/16″ depending on your model), carefully unscrew the heating element from the water heater tank. Turn counterclockwise slowly and steadily. You may notice some residual water drainage when the element begins to loosen – this is normal even after draining the tank. The heating element should come out along with its rubber gasket. Inspect the gasket carefully for deterioration, cracks, or permanent compression. Even if planning to replace the element, keep the old gasket temporarily as a size reference. Examine the element for signs of scale buildup, corrosion, or visible breaks in the element coil, which confirms the need for replacement. Test the thermostat switch to determine if it requires replacement. Locate the two thermostat switches near the top of the water heater assembly – one controls the 12V propane system (wider flat conductor) and one controls the 120V electric system (thinner wire conductor). Focus on the 120V thermostat for electric operation issues. Remove the rubber protective cap covering the reset button. Inspect the wiring connections for any signs of overheating, such as discolored or melted wire insulation, burnt terminals, or loose connections. Disconnect the power wires from the thermostat (typically two wires connected to the bottom terminals). Set your multimeter to continuity or low resistance mode. Place probes on the thermostat terminals – it should show continuity (close to zero ohms) when at normal temperature. If it shows no continuity or if the wiring shows heat damage, replacement is necessary.
Step 3: Installing New Components and Testing
Install the new heating element with proper sealing techniques. Clean the threaded opening in the water heater tank thoroughly, removing any old gasket material, mineral deposits, or corrosion using a clean rag and mild cleaner if needed. Take your new heating element and its accompanying gasket (or purchase a new gasket if not included). Slide the new gasket onto the heating element threads, positioning it against the element’s flange. Carefully thread the heating element into the water heater tank opening by hand, turning clockwise. Hand-tighten as much as possible before using a wrench. Once hand-tight, use your wrench to tighten an additional 1/4 to 1/2 turn – do not overtighten as this can damage the gasket or crack the porcelain lining inside the tank. The element should feel snug and secure with the gasket creating a complete seal. Wire the new heating element following exact specifications. Identify the two terminal posts on the new heating element. Connect the hot (typically black or red) wire from your RV’s electrical system to one terminal and the ground (white or green) wire to the other terminal. Most heating elements are non-polarized, meaning either wire can connect to either terminal. However, always follow the same configuration as the original installation. Use wire nuts or crimp connectors appropriate for outdoor/moisture-exposed applications. Ensure all connections are tight and secure. Wrap each connection with electrical tape for additional protection against moisture. Double-check that no bare wire is exposed and that connections cannot short against the metal water heater housing. If replacing the thermostat, install carefully and reconnect all wiring properly. Remove the old thermostat by disconnecting all wires and removing the mounting screws (typically two screws securing it to the water heater mounting bracket). Position the new thermostat in the exact same location and orientation as the original. Secure it with the mounting screws, ensuring it sits flush against the mounting surface for proper temperature sensing. Reconnect the wires to the new thermostat terminals exactly as they were connected to the old unit – take a photo before disconnecting the old thermostat if you’re unsure of wire positions. The power supply wire (hot) connects to one terminal, and the wire leading to the heating element connects to the other terminal. Ensure all connections are tight and properly insulated. Replace the rubber protective cap over the reset button. Test the entire system thoroughly before returning to normal operation. Close the water heater drain plug securely, tightening it appropriately with your wrench. Turn on the RV’s fresh water supply and open a hot water faucet inside the RV. Allow water to flow until it runs steadily without air bubbles, indicating the tank is completely full and all air has been purged from the system. Close the faucet and inspect the new heating element and all connections for any signs of leakage. Turn on the circuit breaker supplying power to the water heater. Set your digital multimeter to AC voltage mode and carefully test for proper voltage at the heating element terminals – you should read approximately 120 volts (110-125V is normal). Turn on the water heater using the interior control panel switch. Allow 30-45 minutes for a 6-gallon unit or 45-60 minutes for a 10-gallon unit to reach full operating temperature. Test hot water at a faucet to confirm the system is functioning properly. Monitor the first heating cycle to ensure no unusual sounds, smells, or leaks develop.